What the A929_O code means
240V missing or inverter communication failure, an EcoNet fault code (_O = outdoor unit) displayed on the EcoNet Control Center / Universal Outdoor Control (UODC) of a Rheem variable-speed EcoNet air conditioner/heat pump (A18AZ / P18AZ series, Table 15). Response action: lockout while active, short cycle to restart.
Likely causes
- No 240V supply at the outdoor unit (breaker, disconnect or fuse)
- Inverter not communicating with the outdoor control
- Failed inverter drive
How to fix it — step by step
- Check the outdoor unit breaker and disconnect
- If 240V is present, have a technician test inverter communication and the drive
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Inverter drive board.