Navien Water heater Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 33 codes covered.

Finding your model number: it is on the unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

All models

CodeWhat it meansCheck first
E003Ignition failure. The unit runs its ignition sequence and the burner does not light: the service manual…Main gas supply valve closed or gas supply interrupted›
E004False flame detection. The control senses a flame signal when the burner should not be burning.Electrical cord not properly grounded›
E012Flame loss. The burner lit, then the flame went out during operation.Clogged intake air filter starving combustion air›
E016Overheating of the heat exchanger. The heat exchanger exceeded its safe temperature and the unit shut down to…Scale build-up inside the heat exchanger restricting water flow›
E030Exhaust overheating. The exhaust limit shuts the water heater down when the flue temperature exceeds 149 F…Scale build-up in the heat exchanger making exhaust run hot›
E046Abnormal operation: limit control. The high limit control safety device has operated or failed.Tripped or failed limit control›
E047Exhaust thermostat thermistor open or short circuit. The exhaust temperature sensor signal is out of range…Exhaust thermistor failed open or shorted›
E060Abnormal operation: dual venturi. The dual venturi that meters gas and air to the burner is not operating…Dual venturi fault or disconnected venturi›
E109Abnormal operation: fan motor. The combustion fan is not running correctly.Clogged intake air filter restricting the fan›
E110Abnormal air pressure. The unit cannot establish correct combustion air pressure, most often because the…Exhaust pipe obstructed (snow, nest, debris at the termination)›
E407Hot water outlet thermistor open or short circuit. The outlet temperature sensor signal is out of range.Hot water outlet thermistor failed open or shorted›
E421Cold water inlet 1 thermistor open or short circuit. The first inlet temperature sensor signal is out of…Cold water inlet thermistor failed open or shorted›
E432Cold water inlet 2 thermistor open or short circuit. The second inlet temperature sensor signal is out of…Cold water inlet thermistor failed open or shorted›
E434Abnormal operation: water adjustment valve. The motorised water adjustment valve that regulates flow through…Water adjustment valve stuck or failed›
E438Abnormal operation: circulation pump. The recirculation pump is not circulating correctly.External recirculation supply or return lines closed›
E439Abnormal operation: flow sensor. The flow sensor is not reporting water flow correctly.Flow sensor fouled or failed›
E441Hot water inlet 2 thermistor open or short circuit. The second hot water inlet temperature sensor signal is…Hot water inlet thermistor failed open or shorted›
E445Abnormal operation: bypass mixing valve. The bypass mixing valve that blends water to control outlet…Bypass mixing valve stuck or failed›
E515Abnormal operation: PCB. The main control board is operating abnormally.Electrical cord not properly grounded›
E517Abnormal operation: DIP switch setting. A DIP switch setting on the front panel or PCB is incorrect for this…DIP switch set to the wrong position for the gas type, vent length or model›
E593Abnormal operation: front panel key. A front panel key/button fault was detected.Stuck or failed front panel key›
E615Abnormal operation: input and memory. The control board input/memory function is abnormal.PCB input or memory fault›
E736Abnormal operation: cascade communication. Units linked in a cascade system are not communicating.Cascade communication cable or connection fault›
E740Abnormal operation: outdoor temperature sensor. The outdoor temperature sensor is faulty (on the original…Outdoor temperature sensor failed or disconnected›
E760Flushing/service alarm. The unit is due for routine service - a heat exchanger flush is necessary.Service interval reached with scale building up in the heat exchanger›
E782Abnormal operation: main panel communication. The main panel and control are not communicating.Main panel communication fault›
E785Abnormal operation: flow switch/sensor. The flow switch or flow sensor is operating abnormally (on the NPE-2…Flow switch/sensor fouled or failed›
Won't Turn OnA Navien tankless heater needs three supplies before it will turn on — house power for the control board, fan…Tripped breaker, unplugged/failed outlet, or the unit's power switch off — display dark›

NPE-2

CodeWhat it meansCheck first
E031Overheating of the burner. The NPE-2 detected burner overheating and shut down.Scale or debris restricting heat transfer at the burner/heat exchanger›
E594Abnormal operation: EEPROM. The control board's memory (EEPROM) is operating abnormally on the NPE-2.EEPROM / control board memory fault›
E762Vent pipe not properly inserted. The NPE-2 vent installation detector found the vent pipe is not fully seated…Vent pipe pulled out or not inserted to full depth at the exhaust collar›
E773Using the wrong gas. The NPE-2 detected a discrepancy between the gas type set during installation and the…Unit configured for a different gas type than the supply (natural gas vs propane)›
E788Abnormal operation: discrepancy with the gas type setting. On the NPE-2, the gas type on the panel DIP switch…Panel DIP switch gas type setting does not match the panel / supplied gas type›