Navien Water heater NPE-2 E594 Error Code
What the E594 code means
Abnormal operation: EEPROM. The control board's memory (EEPROM) is operating abnormally on the NPE-2.
Likely causes
- EEPROM / control board memory fault
How to fix it — step by step
- Locate the suspect part: the PCB (control board) is in its PCB box behind the front panel (layout: 'Gas Valve / PCB Box' beside the front panel). Access: turn off gas, disconnect power, turn off water, and remove the front cover — the board is then directly reachable; no waterway or gas joints are opened to reach it.
- Before condemning the board, reseat its wiring connectors: an EEPROM/memory fault with a loose multi-pin connector can be a connection problem — disconnect and refit each PCB connector (matching colours/pin types, no excessive force), restore power and check whether E594 clears. Clearing means the fault was a connection; an immediate return confirms the board's memory.
- Replace the PCB (service manual procedure): remove the screws near the top and bottom of the PCB, disconnect all wiring connectors, remove the 2 screws on the back of the case, swap the board, reconnect all connectors, set the proper PCB DIP switch settings for the model, and refit the screws. → Shop the pcb (control board) at Amazon
- Restore water, gas and power, then prove normal operation and temperature control through a hot water draw with no E594 return.
- Tell Navien Technical Support (1-800-519-8794) or the technician: E594 EEPROM abnormality on an NPE-2, and whether reseating the connectors changed anything. What this job involves: board handling inside a gas appliance — power isolated first; the board carries the unit's configuration, so DIP settings must match the model.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - E594 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the PCB (control board).
Parts that commonly fix the E594 code
- PCB (control board)$100–$300Shop at Amazon
- Tools for this job, if you need them$10–$40
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.