Navien Water heater E012 Error Code
What the E012 code means
Flame loss. The burner lit, then the flame went out during operation.
Likely causes
- Clogged intake air filter starving combustion air
- Electrical cord not properly grounded
- Intermittent gas supply
How to fix it — step by step
- Clean the air intake filter: turn the unit off and disconnect power, remove the front cover, remove the screw securing the filter at the top left of the unit, wash the filter with a toothbrush and clean running water, dry it completely, refit it and replace the cover
- Ensure the electrical cord is properly grounded
- Turn the system off for at least 30 minutes, then restart it and run a hot water tap
- If flame loss repeats, work the manual's E012 list before handing over: check the main gas line valve is open, confirm the ground wire is connected and tight, and check the power supply - then test the flame signal itself. The flame rod's check point (the black wire) reads within the manual's 0-10 uA range while the burner fires; a flame that lights but shows almost no signal means the rod is fouled or its ground path is poor - clean the rod tip, confirm the 3.5-4.5 mm igniter gap and the heat-exchanger ground screws, and retest. A healthy signal with continued flame loss points at gas pressure sagging under load: measuring inlet pressure at high fire is the technician step, and the micro-amp reading above is the handover that makes it a short visit
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Flame rod assembly.
Parts that commonly fix the E012 code
- Flame rod assembly$10–$60Shop at Amazon
- Tools for this job, if you need them$10–$40
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
Before you buy: check the flame rod assembly first
Test: Gauge the igniter gap, and on a firing attempt read the flame signal at the flame rod's black check wire (Navien NPE service manual).
A good one reads: Igniter gap 3.5-4.5 mm (1/8 in). Flame current reads within the manual's 0-10 uA check range while firing; near-zero with a clean, correctly gapped rod points at the ground path or the board input, not the rod.
Test values from manualslib.com documentation - confirm against your model's own tech sheet.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.