Navien Water heater E441 Error Code
What the E441 code means
Hot water inlet 2 thermistor open or short circuit. The second hot water inlet temperature sensor signal is out of range.
Likely causes
- Hot water inlet thermistor failed open or shorted
- Damaged or disconnected thermistor wiring
How to fix it — step by step
- Reset the unit first: switch the power off (at the unit's switch or the breaker) for 30 seconds, restore power and run a hot tap - a sensor fault that clears and stays clear through a heating cycle was a transient reading, not a failed part
- With the power off at the breaker, open the front cover and find the hot water inlet thermistor (inlet 2), on the hot water inlet pipe inside the unit: a small sensor on a two-wire connector. Reseat that connector firmly until it latches - a backed-out or corroded plug reads as an open circuit and sets exactly this code
- Inspect the thermistor wiring from the sensor back to the control board for chafing, pinching or rodent damage - insulation worn through so the pair touches reads as a short circuit, the other half of this code
- If you have a multimeter, the confirming test is resistance across the unplugged thermistor: an open (infinite) or near-zero reading condemns the sensor itself, while a plausible resistance that falls steadily as the sensor warms in your hand means the sensor is alive and the fault sits in the wiring or the board input
- Put a number on the sensor before replacing it: stop the unit, let it cool, unplug the thermistor and measure its resistance. Navien's service chart for the inlet/outlet thermistors (blue-blue wires) reads 7.5-10.4 kΩ at 70-80 °F, rising as the water gets colder (11.4-16.4 kΩ at 50-60 °F). Open, shorted or far outside the band for the water's actual temperature condemns the thermistor (Navien part 30008366A); an in-band reading means the sensor is good and the fault is in the wiring or the board input → Shop the hot water inlet thermistor at Amazon
- End point: a sensor proven open or shorted is replaced - the hot water inlet thermistor; a sensor proven good with the code returning means the control board input, which is the technician call (Navien Technical Support 1-800-519-8794), and you can hand over the resistance reading you took instead of paying for the diagnosis twice
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Hot water inlet thermistor.
Parts that commonly fix the E441 code
- Hot water inlet thermistor$25–$80Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
Before you buy: check the hot water inlet thermistor first
Test: Stop the unit, let it cool, unplug the thermistor and measure its resistance at the sensor's actual temperature (Navien NPE service manual chart; the water sensors are the blue-blue wired pair).
A good one reads: Inlet/outlet thermistors: 7.5-10.4 kΩ at 70-80 °F, 11.4-16.4 kΩ at 50-60 °F. The exhaust limit sensor is a different, higher-range part: 41.5-61.3 kΩ at 70-80 °F. Open, shorted or far outside the band for the actual temperature means the sensor has failed.
Test values from manualslib.com documentation - confirm against your model's own tech sheet.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.