Navien Water heater E060 Error Code

What the E060 code means

Abnormal operation: dual venturi. The dual venturi that meters gas and air to the burner is not operating correctly.

Likely causes

  1. Dual venturi fault or disconnected venturi
  2. Gas/air metering fault at the burner

How to fix it — step by step

  1. Locate the suspect part: the dual venturi is coupled to the burner and fan assembly in the upper part of the cabinet (the layout lists 'Dual Venturi Burner' with the fan motor and ignition transformer). Access for all internal parts: turn off gas, power and water, let the unit cool, and remove the front cover (the replacement procedures all start this way; the PCB lives in its PCB box behind the front panel, and the waterway parts are in the lower part of the cabinet above the bottom fittings). This is gas-train work.
  2. Check that the wiring harness to the dual venturi is connected correctly and the cables are not damaged — E060 displays if the wiring is disconnected or the dual venturi malfunctions, so a loose harness is a real first suspect.
  3. Run Navien's dual venturi test: turn power off at the main power switch (not the front panel button), wait 10 seconds, turn power on, wait for Fan Auto Adjusting to complete, then enter Dual Venturi Test Mode and repeat the ON/OFF test at least twice. Listen for the venturi's operating clicks at unit ON and OFF — clicks and correct open/close movement mean the venturi is operating; no noise/movement means it is not (if ambient noise hides it, disassembly and visual inspection are the next step).
  4. Interpretation: if E060 occurs during the test, replace the dual venturi; if the venturi test passes with no E060, replace the APS (air pressure sensor). A venturi that repeatedly opens and closes or will not prove open/closed is replaced, not adjusted. → Shop the dual venturi at Amazon
  5. Replace the dual venturi: gas/power/water off, front cover off, disconnect its harness and its mounting at the burner/fan assembly, fit the new venturi, reconnect, restore supplies, leak-check gas connections with soap solution and prove ignition through full cycles.
  6. Tell the technician: E060, whether the test-mode clicks/movement were present, and the harness condition. What this job involves: gas-train component replacement — gas connections are disturbed and must be leak-tested.
  7. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - E060 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E060 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Navien Water heater error codes

See all Navien water heater codes & guides →