Navien Water heater E004 Error Code

What the E004 code means

False flame detection. The control senses a flame signal when the burner should not be burning.

Likely causes

  1. Electrical cord not properly grounded
  2. Fault in the flame detection circuit

How to fix it — step by step

  1. Ensure the electrical cord is plugged into a properly grounded outlet and the ground connection is intact
  2. Reset the water heater by pressing the Reset button on the front panel (press the Back button on NPE-2 models) and run a hot water tap to confirm it fires
  3. Access, before any internal work: Navien's replacement procedure (service manual S6.1) starts the same way for every part - turn off the electric power, the gas shut-off valve and the water shut-off valve, let the unit cool, and drain the unit before opening any waterway part. The burner, flame rod, igniter and PCB are all behind the front cover. After any repair the manual requires a leak check - soap-bubble solution on every gas joint you opened - and an ignition test before the unit goes back into service
  4. If E004 returns, have a technician inspect the flame detection circuit - a false flame signal is a combustion safety fault, not a reset-and-forget code
  5. Work the manual's E004 checks at the parts themselves: confirm the ground wire is connected and its screws are tight (the first listed check for a false flame), inspect the flame rod for carbon or moisture that can leak a false signal, and check the igniter - the flame rod's igniter gap is 3.5-4.5 mm, and a cracked igniter lead or a transformer sparking with no call for heat can feed the false reading. A rod that cleans up and a ground that was loose explain E004 if it then stays clear through several firing cycles; if E004 returns with the rod clean, the ground proven and no stray spark, the remaining suspect is the PCB's flame-detection input - that is the technician handover, with the rod, gap and ground already proven

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E004 code

Typical pro repair $228–$1,017

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

Before you buy: check the flame rod assembly first

Test: Gauge the igniter gap, and on a firing attempt read the flame signal at the flame rod's black check wire (Navien NPE service manual).

A good one reads: Igniter gap 3.5-4.5 mm (1/8 in). Flame current reads within the manual's 0-10 uA check range while firing; near-zero with a clean, correctly gapped rod points at the ground path or the board input, not the rod.

Test values from manualslib.com documentation - confirm against your model's own tech sheet.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Navien Water heater error codes

See all Navien water heater codes & guides →