Navien Water heater E046 Error Code

What the E046 code means

Abnormal operation: limit control. The high limit control safety device has operated or failed.

Likely causes

  1. Tripped or failed limit control
  2. Heat exchanger overheating driving the limit control

How to fix it — step by step

  1. Turn the unit off and let it cool completely — a limit control operates because something got too hot; do not keep resetting it.
  2. Locate the suspect part: the high limit switch (limit control) is mounted on the primary heat exchanger inside the cabinet (it is shown with the primary heat exchanger in the Layout and Key Components). Access for all internal parts: turn off gas, power and water, let the unit cool, and remove the front cover (the replacement procedures all start this way; the PCB lives in its PCB box behind the front panel, and the waterway parts are in the lower part of the cabinet above the bottom fittings).
  3. Navien's E046 service flow works the heat-exchanger temperature sensing first: check the heat exchanger thermistor connector (CON 6, pins 1 and 2) is seated, then flush the unit and clean the inlet filter and restart — a scaled exchanger overheats and trips the limit. Thermistor resistance within the normal range with a clean, flushed exchanger clears the sensing side; resistance out of range means replace the heat exchanger thermistor.
  4. If sensing tests good and the limit still operates, the limit control itself is tested and replaced if faulty — it is unclipped/unbolted from the heat exchanger and its wires transferred to the new switch.
  5. Tell Navien Technical Support (1-800-519-8794) or the technician: E046, whether the unit was flushed/filter cleaned, and the thermistor resistance result. What this job involves: a safety limit device on a gas heat exchanger — if the limit operated on a genuine overheat, the cause must be corrected, not just the switch swapped. NOTE: the entry names the limit control as the part; Navien's E046 flowchart centres on the heat exchanger thermistor and then the PCB — flagged in the batch notes. → Shop the limit control at Amazon
  6. Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - E046 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E046 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.