Navien Water heater Won't Turn On
What this problem usually means
A Navien tankless heater needs three supplies before it will turn on — house power for the control board, fan and igniter; gas for the burner; and water flow above its minimum activation rate to trigger a heating cycle — and a 'won't turn on' complaint is a failure of one of the three, which the display separates for you. Display dark = the control has no power: breaker, the outlet the unit plugs into, or the unit's own power switch. Display lit but the unit never fires at a tap = it is not seeing enough flow (a clogged cold-water inlet filter is the classic cause) or it is locked out on a code. Display showing an E-code = the unit tried and failed: E003 is ignition failure (it ran the ignition sequence and the burner did not light) and E012 is flame loss (it lit, then the flame went out) — both are code pages, and both point first at gas supply. The gas checks are owner-level: the gas valve at the unit fully open, and on propane, gas actually in the tank.
Likely causes
- Tripped breaker, unplugged/failed outlet, or the unit's power switch off — display dark
- Gas valve at the unit closed or partly closed, or an empty propane tank — display lit, ignition fails (E003 family)
- Clogged cold-water inlet filter or flow below the activation minimum — display lit, unit never attempts to fire
- Ignition failure with gas proven: failed igniter or flame sensor — reported as E003/E012 rather than silence
- Failed control board: outlet proven live, power switch on, display still dark
How to fix it — step by step
- Read the display first — it is the whole branch test. DARK: go to step 2 (power). LIT with an E-code: note the code — E003 means ignition failure and E012 means flame loss; do step 3 (gas) once, and if the code returns, work that code's page. LIT, no code, no firing at a tap: go to step 4 (flow)
- Power branch: check the breaker for the heater's circuit and reset it if tripped (trips again = leave it off and say so to the technician). Confirm the unit's power cord is fully plugged in and test the outlet with another device — a dead outlet is a house fault. Confirm the unit's own power switch is on. Outlet live + switch on + display still dark after a one-minute power-cycle = the control board has failed; that is the pinpoint, and board work inside a gas appliance is a technician's job → Shop the control board at Amazon
- Gas branch: find the gas shutoff valve on the line at the unit and confirm the handle is fully open (parallel with the pipe). On propane, confirm there is gas in the tank. Then run a hot tap and listen: fan running and ignition clicking followed by an E003 means the sequence ran and no flame was established — with the valve open and gas in the tank, the remaining suspects are the igniter and the gas valve inside the unit, both technician parts. Never open gas connections yourself
- Flow branch: a Navien only fires when flow through it passes its activation minimum, so open one hot tap fully — a cracked-open tap is not a test. Still nothing: close the unit's isolation valves and clean the cold-water inlet filter (the screen at the cold inlet), reopen the valves fully and retest. Filter clean + full flow + still no attempt = the flow sensor is not reporting — the terminal pinpoint for the technician
- Reset once, deliberately: switch the unit off and back on (or cycle its breaker) to clear a transient lockout, then run a full-flow hot tap. A code that returns immediately is not transient — stop resetting and hand over the code; repeated resets do not fix ignition or flame faults
- Verify under a real draw: burner fires at one fully open tap, outlet temperature reaches the setpoint and holds, and the display stays code-free through a full shower-length draw — then open a second tap to confirm it keeps firing rather than dropping out
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the igniter.
Also tied to this fault: flame sensor - Shop at Amazon; inlet filter screen - Shop at Amazon; flow sensor - Shop at Amazon; control board - Shop at Amazon; gas valve - Shop at Amazon
Parts that commonly fix it
- igniterShop at Amazon
- flame sensor$10–$60Shop at Amazon
- inlet filter screen$5–$20Shop at Amazon
- flow sensorShop at Amazon
- control board$100–$300Shop at Amazon
- gas valve$115–$500Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number