Navien NPE-2 Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 5 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E031 | Overheating of the burner. The NPE-2 detected burner overheating and shut down. | Scale or debris restricting heat transfer at the burner/heat exchanger | › |
| E594 | Abnormal operation: EEPROM. The control board's memory (EEPROM) is operating abnormally on the NPE-2. | EEPROM / control board memory fault | › |
| E762 | Vent pipe not properly inserted. The NPE-2 vent installation detector found the vent pipe is not fully seated… | Vent pipe pulled out or not inserted to full depth at the exhaust collar | › |
| E773 | Using the wrong gas. The NPE-2 detected a discrepancy between the gas type set during installation and the… | Unit configured for a different gas type than the supply (natural gas vs propane) | › |
| E788 | Abnormal operation: discrepancy with the gas type setting. On the NPE-2, the gas type on the panel DIP switch… | Panel DIP switch gas type setting does not match the panel / supplied gas type | › |
All Navien water heater models & codes →