Navien Water heater E047 Error Code

What the E047 code means

Exhaust thermostat thermistor open or short circuit. The exhaust temperature sensor signal is out of range, so the control cannot trust exhaust temperature.

Likely causes

  1. Exhaust thermistor failed open or shorted
  2. Damaged or disconnected exhaust thermistor wiring

How to fix it — step by step

  1. Reset the unit first: switch the power off (at the unit's switch or the breaker) for 30 seconds, restore power and run a hot tap - a sensor fault that clears and stays clear through a heating cycle was a transient reading, not a failed part
  2. With the power off at the breaker, open the front cover and find the exhaust thermistor, mounted in the exhaust path at the top of the unit: a small sensor on a two-wire connector. Reseat that connector firmly until it latches - a backed-out or corroded plug reads as an open circuit and sets exactly this code
  3. Inspect the thermistor wiring from the sensor back to the control board for chafing, pinching or rodent damage - insulation worn through so the pair touches reads as a short circuit, the other half of this code
  4. If you have a multimeter, the confirming test is resistance across the unplugged thermistor: an open (infinite) or near-zero reading condemns the sensor itself, while a plausible resistance that falls steadily as the sensor warms in your hand means the sensor is alive and the fault sits in the wiring or the board input
  5. Put a number on the sensor before replacing it: stop the unit, let it cool, unplug the exhaust thermistor and measure its resistance. It is a different, higher-range part than the water thermistors - Navien's service chart reads 41.5-61.3 kΩ at 70-80 °F for the exhaust limit sensor (part 30009478A), so do not judge it against the water sensors' numbers. Open, shorted or far outside the band condemns it; an in-band reading leaves the wiring or the board input → Shop the exhaust thermistor at Amazon
  6. End point: a sensor proven open or shorted is replaced - the exhaust thermistor; a sensor proven good with the code returning means the control board input, which is the technician call (Navien Technical Support 1-800-519-8794), and you can hand over the resistance reading you took instead of paying for the diagnosis twice

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E047 code

Parts run $25–$80Typical pro repair $228–$1,017Fixing it yourself typically saves $148–$992
  • Exhaust thermistor$25–$80Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

Before you buy: check the exhaust thermistor first

Test: Stop the unit, let it cool, unplug the thermistor and measure its resistance at the sensor's actual temperature (Navien NPE service manual chart; the water sensors are the blue-blue wired pair).

A good one reads: Inlet/outlet thermistors: 7.5-10.4 kΩ at 70-80 °F, 11.4-16.4 kΩ at 50-60 °F. The exhaust limit sensor is a different, higher-range part: 41.5-61.3 kΩ at 70-80 °F. Open, shorted or far outside the band for the actual temperature means the sensor has failed.

Test values from manualslib.com documentation - confirm against your model's own tech sheet.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Navien Water heater error codes

See all Navien water heater codes & guides →