Navien Water heater E740 Error Code
What the E740 code means
Abnormal operation: outdoor temperature sensor. The outdoor temperature sensor is faulty (on the original NPE; on the NPE-2 this code is scoped to units with an installed air handler unit, AHU).
Likely causes
- Outdoor temperature sensor failed or disconnected
- Sensor wiring fault
How to fix it — step by step
- Understand what sets it (Navien NPE Service Manual): E740 sets when the outdoor temperature sensor's resistance reads under 2.2 kΩ or over 122.2 kΩ continuously for 3 seconds — an open, shorted or disconnected sensor circuit. The heater does not stop; it abandons the outdoor Reset Curve and falls back to Normal mode, so the symptom is lost weather-compensation, not lost hot water. → Shop the outdoor temperature sensor at Amazon
- Where the sensor lives: this sensor is external — none is inside the heater. Per Navien's outdoor sensor instructions (30012950A) it mounts on an exterior wall, out of direct sun and away from heat sources, exhaust vents, windows and doors, at least 5 feet above the ground, with its two wires run to the outdoor-sensor terminals on the heater's control board (polarity is typically not critical). Access for the sensor itself is at its outdoor mounting — no disassembly of the heater is needed.
- First check the sensor's connector and wiring for water ingress or leakage at the connection — the first check for this code — then measure the sensor's resistance: a reading inside the 2.2–122.2 kΩ window with the code still set sends the check to the parameter setting and then the control board; a reading outside the window condemns the sensor.
- Replace a failed sensor at its outdoor mounting, re-make the two-wire connection to the board terminals, and confirm the unit returns to Reset Curve operation with E740 clear.
- Navien Technical Support (1-800-519-8794) remains the documented contact if the sensor and wiring test good and the code persists.
- Verify after the repair: restore gas, water and power, then open a hot tap and let the heater fire and run for several minutes - E740 should stay clear through the whole draw. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor temperature sensor.
Parts that commonly fix the E740 code
- Outdoor temperature sensor$25–$80Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.