American Standard Furnace A801X (Silver 80, 7 segment display control) E6.3 Error Code
What the E6.3 code means
Igniter circuit fault. The igniter relay failed or the igniter itself is open, so the furnace cannot light.
Likely causes
- Igniter relay on the control failed
- Igniter element cracked or burned open
- Igniter plug loose at the control
How to fix it — step by step
- Turn the power off before touching the igniter. It is fragile and runs extremely hot.
- Remove the burner door and find the igniter in front of the burners. Check the element for cracks or white burn spots.
- Follow the igniter wires to the control plug and reseat it.
- Test the igniter with a meter set to ohms with the plug disconnected. An open reading confirms the igniter has failed.
- If the igniter tests good and has no power during a call for heat, the igniter relay on the control has failed and the board must be replaced.
- Replace a failed igniter by its base only. Skin oil on the element shortens its life.
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E6.3 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the hot surface igniter.
Shop the hot surface igniter at Amazon
Also tied to this fault: integrated furnace control - Shop at Amazon
Parts that commonly fix the E6.3 code
- hot surface igniter$15–$85Shop at Amazon
- integrated furnace controlShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related American Standard Furnace A801X (Silver 80, 7 segment display control) error codes