American Standard A801X (Silver 80, 7 segment display control) Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 15 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| E0 | Internal failure. The integrated furnace control has failed an internal check and cannot run the furnace. | Internal failure inside the integrated furnace control | › |
| E04 | Open limit circuit. The main thermal limit, a flame rollout switch, or the reverse airflow switch has opened… | Dirty air filter or restricted ductwork overheating the furnace | › |
| E05 | Flame detected when it should not be present. The control sees a flame signal while the gas valve is off. | Gas valve leaking through or closing slowly | › |
| E08 | Flame current low, but operation is still allowed. The flame signal is weak and the furnace keeps running for… | Flame sensor coated or oxidized | › |
| E11 | Gas valve circuit fault group. See the troubleshooting instructions. The control has logged one of several… | Gas valve not energized when it should be | › |
| E12 | Open fuse. The low voltage fuse on the integrated furnace control has blown, so the control has no 24 volt… | Short in the thermostat wiring blowing the board fuse | › |
| E2.1 | Retries exceeded. Flame was never sensed, and after 3 tries the control locked out for one hour. | Gas supply off or low pressure | › |
| E2.2 | Recycles exceeded. Flame was sensed, then lost, and after 10 losses the control locked out for one hour. | Dirty flame sensor dropping the signal | › |
| E2.3 | First stage gas valve not energized when it should be. The fault repeated 10 times, so the control flagged… | Gas valve relay on the control not sending power to the valve | › |
| E3.1 | Shorted pressure switch, first stage. The control sees the pressure switch closed before the inducer starts. | Pressure switch contacts stuck closed | › |
| E3.2 | Open pressure switch. The inducer runs but the pressure switch never closes, so the ignition sequence stops. | Blocked vent or intake pipe | › |
| E6.1 | Reversed polarity on the high voltage supply. Line and neutral are swapped at the furnace. | Line and neutral swapped at the furnace disconnect or junction box | › |
| E6.2 | Faulty ground. The control does not see a proper ground for the furnace. | Ground wire loose or not bonded to the cabinet | › |
| E6.3 | Igniter circuit fault. The igniter relay failed or the igniter itself is open, so the furnace cannot light. | Igniter relay on the control failed | › |
| E7.1 | Gas valve energized when it should not be. The first stage gas valve output is on with no call for heat. | Gas valve relay stuck closed on the control | › |
All American Standard furnace models & codes →