American Standard Furnace A801X (Silver 80, 7 segment display control) E11 Error Code
What the E11 code means
Gas valve circuit fault group. See the troubleshooting instructions. The control has logged one of several gas valve relay or valve response faults under this code.
Likely causes
- Gas valve not energized when it should be
- Gas valve relay stuck closed
- Second stage gas valve relay fault on two stage wired controls
- Gas valve energized when it should not be
How to fix it — step by step
- E11 is a pointer code. The manual sends you to the gas valve troubleshooting flowcharts rather than one single cause.
- Turn the power off and close the gas shutoff before testing the valve circuit.
- Check the gas valve plug and the wires back to the control for damage or loose pins.
- On a call for heat, a pro test is 24 volts at the valve at the right point in the sequence. Voltage with no opening means a failed valve. No voltage, or voltage with no call, means a failed control relay.
- Gas valve and control replacement are pro work. Do not open the valve body.
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E11 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas valve.
Also tied to this fault: integrated furnace control - Shop at Amazon
Parts that commonly fix the E11 code
- gas valve$100–$355Shop at Amazon
- integrated furnace controlShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.