American Standard Furnace A801X (Silver 80, 7 segment display control) E2.2 Error Code
What the E2.2 code means
Recycles exceeded. Flame was sensed, then lost, and after 10 losses the control locked out for one hour.
Likely causes
- Dirty flame sensor dropping the signal
- Low or interrupted gas pressure
- Weak flame from a restricted vent or intake
- Faulty gas valve
How to fix it — step by step
- Turn the power off before removing parts.
- Find the flame sensor rod in the flame path, remove its screw, and clean the rod with fine steel wool until bright.
- Measure the flame current if you have the test pads and a meter. The manual gives a normal range of 0.75 to 3.0 microamps at the FP pads on the control. A reading under that range after cleaning points away from the sensor.
- Check the vent and intake pipes for partial blockage.
- Restore power and watch a full cycle. Flame that still drops repeatedly with a clean sensor and clear venting needs a pro to check gas pressure under load and the gas valve.
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E2.2 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the flame sensor.
Shop the flame sensor at Amazon
Also tied to this fault: gas valve - Shop at Amazon
Parts that commonly fix the E2.2 code
- flame sensor$10–$60Shop at Amazon
- gas valve$100–$355Shop at Amazon
- Tools for this job, if you need them$10–$40
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related American Standard Furnace A801X (Silver 80, 7 segment display control) error codes
See all American Standard A801X (Silver 80, 7 segment display control) codes & guides →