What the E04 code means
Open limit circuit. The main thermal limit, a flame rollout switch, or the reverse airflow switch has opened and stopped the heating cycle.
Likely causes
- Dirty air filter or restricted ductwork overheating the furnace
- Flame rollout tripping a rollout switch
- Reverse airflow switch open on downflow or horizontal installs
- Failed limit switch or loose limit wiring
How to fix it — step by step
- This code covers three switches on one circuit: the main thermal limit, the flame rollout switches, and the reverse airflow switch. Work out which one opened before replacing anything.
- If you see scorching above the burners, stop. That is rollout. Turn the gas off and call a pro.
- With no rollout signs, turn the power off and replace a dirty air filter, then open closed registers.
- Restore power and call for heat. A code that clears as the furnace cools and does not return points to airflow.
- If E04 shows on a cold furnace, turn the power off, find each switch on the limit circuit, and test them one by one with a meter. The one that reads open when cold is the failed part, or the one protecting a real fault.
- Replace only a switch proven open when cold and correct the airflow cause, or the new switch will trip too.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the air filter.
Also tied to this fault: main limit switch - Shop at Amazon; flame rollout switch - Shop at Amazon
Parts that commonly fix the E04 code
- air filter$5–$30Shop at Amazon
- main limit switch$5–$35Shop at Amazon
- flame rollout switch$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related American Standard Furnace A801X (Silver 80, 7 segment display control) error codes
See all American Standard A801X (Silver 80, 7 segment display control) codes & guides →