American Standard Furnace A801X (Silver 80, 7 segment display control) E08 Error Code
What the E08 code means
Flame current low, but operation is still allowed. The flame signal is weak and the furnace keeps running for now.
Likely causes
- Flame sensor coated or oxidized
- Sensor at the edge of the flame
- Weak flame from low gas pressure
How to fix it — step by step
- The furnace still runs on this code. It is a warning to service the flame sensing before it becomes a lockout.
- Turn the power off, remove the flame sensor, and clean the rod with fine steel wool until bright.
- Reinstall the sensor fully in the flame path and restore power.
- Measure flame current at the FP pads on the control if you have a meter. The manual range is 0.75 to 3.0 microamps. A reading still below range with a clean sensor points to gas pressure or flame quality. → Shop the flame sensor at Amazon
- Call a pro to check manifold pressure if cleaning did not restore the signal.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E08 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the flame sensor.
Parts that commonly fix the E08 code
- flame sensor$10–$60Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.