American Standard Furnace A801X (Silver 80, 7 segment display control) E2.3 Error Code
What the E2.3 code means
First stage gas valve not energized when it should be. The fault repeated 10 times, so the control flagged the gas valve circuit.
Likely causes
- Gas valve relay on the control not sending power to the valve
- Broken wire between the control and the gas valve
- Failed gas valve solenoid
How to fix it — step by step
- This code is about the gas valve circuit, so turn the power off and close the gas shutoff before testing.
- Find the gas valve at the burner manifold and check its plug and wires back to the control board for damage or loose pins.
- Restore power and call for heat. After the igniter warm up, test for 24 volts at the gas valve terminals. Voltage present with no valve opening means the valve has failed. No voltage means the control relay or wiring has failed. → Shop the gas valve at Amazon
- Gas valve and control board replacement are pro work. Do not open the gas valve body.
- Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E2.3 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas valve.
Also tied to this fault: integrated furnace control - Shop at Amazon
Parts that commonly fix the E2.3 code
- gas valve$100–$355Shop at Amazon
- integrated furnace controlShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.