American Standard Furnace Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 15 codes covered.

Finding your model number: it is inside the blower/burner compartment door.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

A801X (Silver 80, 7 segment display control)

CodeWhat it meansCheck first
E0Internal failure. The integrated furnace control has failed an internal check and cannot run the furnace.Internal failure inside the integrated furnace control›
E04Open limit circuit. The main thermal limit, a flame rollout switch, or the reverse airflow switch has opened…Dirty air filter or restricted ductwork overheating the furnace›
E05Flame detected when it should not be present. The control sees a flame signal while the gas valve is off.Gas valve leaking through or closing slowly›
E08Flame current low, but operation is still allowed. The flame signal is weak and the furnace keeps running for…Flame sensor coated or oxidized›
E11Gas valve circuit fault group. See the troubleshooting instructions. The control has logged one of several…Gas valve not energized when it should be›
E12Open fuse. The low voltage fuse on the integrated furnace control has blown, so the control has no 24 volt…Short in the thermostat wiring blowing the board fuse›
E2.1Retries exceeded. Flame was never sensed, and after 3 tries the control locked out for one hour.Gas supply off or low pressure›
E2.2Recycles exceeded. Flame was sensed, then lost, and after 10 losses the control locked out for one hour.Dirty flame sensor dropping the signal›
E2.3First stage gas valve not energized when it should be. The fault repeated 10 times, so the control flagged…Gas valve relay on the control not sending power to the valve›
E3.1Shorted pressure switch, first stage. The control sees the pressure switch closed before the inducer starts.Pressure switch contacts stuck closed›
E3.2Open pressure switch. The inducer runs but the pressure switch never closes, so the ignition sequence stops.Blocked vent or intake pipe›
E6.1Reversed polarity on the high voltage supply. Line and neutral are swapped at the furnace.Line and neutral swapped at the furnace disconnect or junction box›
E6.2Faulty ground. The control does not see a proper ground for the furnace.Ground wire loose or not bonded to the cabinet›
E6.3Igniter circuit fault. The igniter relay failed or the igniter itself is open, so the furnace cannot light.Igniter relay on the control failed›
E7.1Gas valve energized when it should not be. The first stage gas valve output is on with no call for heat.Gas valve relay stuck closed on the control›
Looking for a part?

Once you know the part you need, browse American Standard Furnace replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.