American Standard Furnace A801X (Silver 80, 7 segment display control) E05 Error Code
What the E05 code means
Flame detected when it should not be present. The control sees a flame signal while the gas valve is off.
Likely causes
- Gas valve leaking through or closing slowly
- Flame sensor wire shorted to the cabinet
- Control sensing a flame signal that is not real
How to fix it — step by step
- Treat this as a gas safety fault. Turn the power off and close the gas shutoff to the furnace.
- If you smell gas, leave the building and call the gas supplier from outside.
- With the gas off, inspect the flame sensor wire for chafed insulation touching metal and repair any short.
- Confirm the burners are fully out. Flame with the valve commanded off means the valve is leaking.
- Do not run the furnace on this code. A leaking gas valve is replaced by a pro.
- Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E05 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the gas valve.
Parts that commonly fix the E05 code
- gas valve$100–$355Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related American Standard Furnace A801X (Silver 80, 7 segment display control) error codes
See all American Standard A801X (Silver 80, 7 segment display control) codes & guides →