American Standard Furnace A801X (Silver 80, 7 segment display control) E2.1 Error Code

What the E2.1 code means

Retries exceeded. Flame was never sensed, and after 3 tries the control locked out for one hour.

Likely causes

  1. Gas supply off or low pressure
  2. Failed hot surface igniter
  3. Dirty flame sensor
  4. Gas valve not opening

How to fix it — step by step

  1. Turn the power off and close the gas shutoff before working inside the furnace.
  2. Confirm the gas shutoff valve to the furnace is open and other gas appliances in the home work.
  3. Remove the burner door and find the igniter in front of the burners. Check for cracks or burn marks.
  4. Restore power and call for heat. The inducer starts, the igniter warms up for about 17 seconds, then the gas valve should open. An igniter that never glows has failed. → Shop the gas valve at Amazon
  5. If the burners light and drop out, turn the power off and clean the flame sensor rod with fine steel wool. Proof of flame must happen within 4 seconds on this control.
  6. Three failed tries start the one hour lockout. If gas, igniter, and sensor all check out, call a pro to test the gas valve and manifold pressure.
  7. Verify after the repair: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E2.1 should stay clear for the whole cycle. If it comes back, the repair did not cure it: hand over the point in the sequence where it reappears, because that timing is the diagnosis

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E2.1 code

Typical pro repair $150–$500

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related American Standard Furnace A801X (Silver 80, 7 segment display control) error codes