What the E3.1 code means

Shorted pressure switch, first stage. The control sees the pressure switch closed before the inducer starts.

Likely causes

  1. Pressure switch contacts stuck closed
  2. Water or debris in the switch hose holding it closed
  3. Short in the switch wiring

How to fix it — step by step

  1. Turn the power off before opening the blower compartment.
  2. Find the pressure switch near the inducer, a round switch with a rubber hose and two wires.
  3. Pull the hose and check it for water or debris, and clear the port on the inducer housing.
  4. With the inducer off, test the switch with a meter. Continuity with no draft means the switch is stuck closed.
  5. Repair any damaged switch wiring. If the switch stays closed with a clear hose, replace it with the correct setpoint part.
  6. Verify the fix: restore power and run a full heat call from the thermostat and watch one complete heating cycle - ignition, steady burn and shutoff - E3.1 should stay clear for the whole cycle. If it comes back, the fault is still present: recheck the step above whose result was borderline, and treat the part that step points to as the one to replace

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the E3.1 code

Parts run $50–$205Typical pro repair $133–$505
  • pressure switch$50–$205Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related American Standard Furnace A801X (Silver 80, 7 segment display control) error codes

See all American Standard A801X (Silver 80, 7 segment display control) codes & guides →