What the LC code means
LC is a malfunction of transmission between the control PCB and the inverter PCB (SM-TS3) — the outdoor unit's two boards have stopped exchanging data. It is the outdoor-internal counterpart to U4's indoor-outdoor link failure. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Loose or damaged interconnect between control and inverter PCBs
- Defective inverter PCB
- Defective control (outdoor) PCB
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code)
- Breaker off. Open the outdoor control box and check the board-to-board interconnect: connectors seated, no heat damage or corrosion — a disturbed link inside the box is the cheap cause
- Restore power and re-test: communication restored by reseating was the connection
- If LC persists, one of the two boards is at fault, separated by substitution at the shop. Hand over the pinpoint: LC confirmed, internal interconnect verified
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outdoor unit PCB.
Parts that commonly fix the LC code
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →