Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) U1 Error Code
What the U1 code means
U1 is a reverse phase / open phase fault in the power supply (SM-TS3). The system has detected that its incoming supply phases are reversed or that a phase is missing. On residential ductless systems this appears after electrical work — a replaced breaker, a rewired disconnect, or utility-side work — rather than from wear. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Reversed phase in the supply wiring
- Open (missing) phase in the supply
- Loose supply connection at the outdoor unit
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code). U1 is a supply fault, so the air conditioner itself is the witness, not the suspect
- Breaker off. If any electrical work was done recently (panel, disconnect, breaker, the unit's own power wiring), that work is the first suspect — the phase order or a dropped phase dates from it
- A qualified electrician or HVAC technician verifies the supply at the outdoor unit: all phases present, in the correct order, connections tight. Correcting phase order is supply work, not an air-conditioner part
- Hand a shop this pinpoint: U1 confirmed, and what electrical work preceded it — that history is usually the whole diagnosis
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outdoor unit PCB.
Parts that commonly fix the U1 code
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →