Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) U3 Error Code
What the U3 code means
U3 means the check operation has not been executed, or a transmission error occurred in that context (SM-TS3). The check operation is the commissioning run a Daikin system performs after installation or a board replacement so the units learn the system; U3 says that handshake never completed. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Check operation never run after installation
- Check operation not re-run after a PCB replacement
- Transmission error during the check operation
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code). U3 on a brand-new install or right after a board swap is expected until commissioning is finished — context decides this code
- If the system was just installed or a board was just replaced, the fix is procedural: the installer runs the check operation per the installation manual, which clears U3 when the system sets correctly
- If U3 appears on a long-running system with no recent work, treat it as the transmission-error variant: breaker off, check the indoor-outdoor interconnect wiring and connectors, restore power and re-test
- Hand a shop this pinpoint: U3 confirmed, whether the system is newly installed or a board was recently changed, and the wiring state you found
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the indoor unit PCB.
Shop the indoor unit PCB at Amazon
Also tied to this fault: outdoor unit PCB - Shop at Amazon
Parts that commonly fix the U3 code
- indoor unit PCB$80–$400Shop at Amazon
- outdoor unit PCB$80–$400Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →