Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) P1 Error Code
What the P1 code means
P1 is a power voltage imbalance, or an inverter PCB malfunction (SM-TS3 gives the code both readings). The supply phases feeding the inverter are imbalanced, or the board measuring them is wrong — the code deliberately covers both ends of that measurement. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.
Likely causes
- Power voltage imbalance in the supply
- Defective inverter PCB (measurement or itself)
- Loose supply connection at the outdoor unit
How to fix it — step by step
- Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code)
- Breaker off. Check the supply connections at the outdoor unit for tightness — a loose leg is an imbalance you can fix with a screwdriver (power off, and only if you are competent to open the disconnect; otherwise this is the technician's first check too)
- The separation of supply from board requires measuring the incoming phases: balanced supply at the unit with P1 persisting condemns the inverter PCB; imbalanced supply is corrected at the electrical installation
- Hand a shop this pinpoint: P1 confirmed, connection state, and any recent electrical work — P1, like U1, often dates from a supply change
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the outdoor unit PCB.
Parts that commonly fix the P1 code
- outdoor unit PCB$80–$400Shop at Amazon
- Tools for this job, if you need them$10–$40
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.
Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes
See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →