Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) P1 Error Code

What the P1 code means

P1 is a power voltage imbalance, or an inverter PCB malfunction (SM-TS3 gives the code both readings). The supply phases feeding the inverter are imbalanced, or the board measuring them is wrong — the code deliberately covers both ends of that measurement. This code belongs to Daikin's unified residential ductless malfunction table (SM-TS3), shared across the FTXS/FDXS/FTXM/RMXS families; pull it with the remote self-diagnosis before acting on it.

Likely causes

  1. Power voltage imbalance in the supply
  2. Defective inverter PCB (measurement or itself)
  3. Loose supply connection at the outdoor unit

How to fix it — step by step

  1. Confirm the code with the remote self-diagnosis first (hold TIMER CANCEL for 5 seconds until 00 shows, then press it repeatedly until the long beep marks the stored code)
  2. Breaker off. Check the supply connections at the outdoor unit for tightness — a loose leg is an imbalance you can fix with a screwdriver (power off, and only if you are competent to open the disconnect; otherwise this is the technician's first check too)
  3. The separation of supply from board requires measuring the incoming phases: balanced supply at the unit with P1 persisting condemns the inverter PCB; imbalanced supply is corrected at the electrical installation
  4. Hand a shop this pinpoint: P1 confirmed, connection state, and any recent electrical work — P1, like U1, often dates from a supply change

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the P1 code

Parts run $80–$400Typical pro repair $450–$2,000Fixing it yourself typically saves $50–$1,920
  • outdoor unit PCB$80–$400Shop at Amazon
  • Tools for this job, if you need them$10–$40

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the unit's rating plate. It's the key to the right manual pages and the right parts.

Related Daikin Air Conditioner Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) error codes

See all Daikin Ductless Mini-Split (FTXS / FDXS / FTXM / RMXS) codes & guides →