Bryant Heat pump 286A / 288A 31 Error Code
What the 31 code means
High Pressure Switch Open — a high-pressure switch trip, read as 3 short and 1 long flash on the amber status LED. The Bryant manual directs checking refrigerant charge, outdoor fan operation and coils for airflow restrictions. The table's sequence note applies: the compressor contactor is de-energized, the outdoor fan runs for up to 15 minutes, and the control retries after the delay while demand exists. Repeated trips escalate to the code 84 high-pressure lockout, so the cause must be found, not reset away.
Likely causes
- Outdoor coil blocked or fouled restricting airflow
- Outdoor fan motor not running correctly
- Refrigerant overcharge
- Refrigerant circuit restriction
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Technician: verify full outdoor fan operation, clean/inspect the outdoor coil, then check charge with gauges by the manual's method and test the high-pressure switch and harness against actual pressure.
- Pinpoint: correct the airflow, fan or charge cause; normal pressure with a tripping switch pinpoints the switch/harness — refrigerant work is EPA-certified technician only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor fan motor.
Parts that commonly fix the 31 code
- Outdoor fan motorShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.