Bryant Heat pump 286A / 288A 73 Error Code

What the 73 code means

Contactor Shorted — compressor voltage is sensed when no demand for compressor operation exists, read as 7 short and 3 long flashes. The Bryant manual states the contactor may be stuck closed or there is a wiring error. The compressor is being powered when it should be off, which can mean uncommanded running and no proper shutdown. Isolate the unit at the disconnect and treat this as a stop-and-fix fault rather than resetting and monitoring it.

Likely causes

  1. Contactor contacts welded/stuck closed
  2. Wiring error or short powering the compressor circuit
  3. Control board fault holding the contactor coil energized
  4. Debris preventing the contactor from opening

How to fix it — step by step

  1. Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
  2. Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
  3. Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
  4. Technician, with no demand: load-side compressor voltage present with no coil voltage pinpoints welded Contactor contacts; coil voltage present with no call pinpoints a control or wiring fault feeding the coil.
  5. Pinpoint: replace a stuck Contactor; if the contactor itself opens correctly, follow the coil-voltage finding to the Control board or wiring error.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 73 code

Parts run $10–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bryant Heat pump 286A / 288A error codes

See all Bryant 286A / 288A codes & guides →