Bryant Heat pump 286A / 288A 71 Error Code
What the 71 code means
Low Stage Thermal Cutout — compressor operation is detected then disappears while low stage demand exists, read as 7 short and 1 long flash. The Bryant manual lists possible causes as an internal compressor overload trip, or a start relay and capacitor held in circuit too long if installed. The sequence note applies: the contactor de-energizes, the outdoor fan runs up to 15 minutes, and the control retries. Three consecutive-cycle cutouts escalate to the code 81 low stage thermal lockout.
Likely causes
- Internal compressor overload trip
- Start relay/capacitor held in circuit too long
- High pressure or poor airflow overheating the compressor
- Contactor or wiring dropping compressor voltage
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Technician, after cool-down: test capacitor values and the start relay, measure compressor windings and running amps, and check pressures/airflow for the overheating cause behind the overload trip.
- Pinpoint: replace a failed Run capacitor, relay or Contactor if found; correct electrics and pressures with repeated trips pinpoint the compressor itself — technician-only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Run capacitor.
Shop the Run capacitor at Amazon
Also tied to this fault: Contactor - Shop at Amazon
Parts that commonly fix the 71 code
- Run capacitor$5–$35Shop at Amazon
- Contactor$10–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.