Bryant Heat pump 286A / 288A 71 Error Code

What the 71 code means

Low Stage Thermal Cutout — compressor operation is detected then disappears while low stage demand exists, read as 7 short and 1 long flash. The Bryant manual lists possible causes as an internal compressor overload trip, or a start relay and capacitor held in circuit too long if installed. The sequence note applies: the contactor de-energizes, the outdoor fan runs up to 15 minutes, and the control retries. Three consecutive-cycle cutouts escalate to the code 81 low stage thermal lockout.

Likely causes

  1. Internal compressor overload trip
  2. Start relay/capacitor held in circuit too long
  3. High pressure or poor airflow overheating the compressor
  4. Contactor or wiring dropping compressor voltage

How to fix it — step by step

  1. Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
  2. Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
  3. Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
  4. Technician, after cool-down: test capacitor values and the start relay, measure compressor windings and running amps, and check pressures/airflow for the overheating cause behind the overload trip.
  5. Pinpoint: replace a failed Run capacitor, relay or Contactor if found; correct electrics and pressures with repeated trips pinpoint the compressor itself — technician-only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 71 code

Parts run $5–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bryant Heat pump 286A / 288A error codes