Bryant Heat pump 286A / 288A 55 Error Code
What the 55 code means
Outdoor Coil Sensor Fault — the coil sensor is not reading or is out of range, read as 5 short and 5 long flashes. The Bryant manual directs ohming out the sensor and checking wiring. In the Bryant variable-speed service literature the failed-coil-sensor default is explicit: defrost occurs at each time interval during heating but terminates after 2 minutes, which cannot keep a coil clear in hard frost — so code 55 in heating season shows up as a progressively icing outdoor coil and falling heat output.
Likely causes
- Failed or drifted coil thermistor
- Sensor loose or clipped to the wrong tube
- Open, shorted or corroded sensor harness
- Outdoor control board sensor input damage
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Verify the coil sensor is properly clipped to its tube, then with power OFF ohm it out against the manual's curve at the measured coil temperature and check harness continuity; compare its reading plausibility against the outdoor air sensor.
- Pinpoint: replace the Thermistor/Defrost sensor if out of specification or badly mounted; correct sensor and wiring with a persistent 55 pinpoints the Control board input. → Shop the thermistor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Defrost sensor - Shop at Amazon
Parts that commonly fix the 55 code
- Thermistor$25–$80Shop at Amazon
- Defrost sensor$25–$80Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.