Bryant 286A / 288A Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 18 codes covered.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| 16 | System Communications Failure — communication with the User Interface (Evolution Control) is lost, and the… | Loose or damaged communication wiring to the Evolution Control, indoor or outdoor unit | › |
| 25 | Invalid Model Plug — the Bryant control does not detect a model plug or detects an invalid model plug, and… | Model plug missing after a board replacement | › |
| 31 | High Pressure Switch Open — a high-pressure switch trip, read as 3 short and 1 long flash on the amber status… | Outdoor coil blocked or fouled restricting airflow | › |
| 32 | Low Pressure Switch Open — a low-pressure switch trip, and the Bryant manual's own example for reading the… | Low refrigerant charge from a leak | › |
| 45 | Control Fault — the Bryant manual states the outdoor unit control board has failed and the control board… | Failed outdoor control board circuitry | › |
| 46 | Brown Out (230V) — line voltage was less than 187 volts for at least 4 seconds, read as 4 short and 6 long… | Utility voltage dip or sustained low voltage | › |
| 47 | No 230V at Unit — there is no 230 volts at the contactor when the indoor unit is powered and cooling or… | Outdoor disconnect open or failed | › |
| 53 | Outdoor Air Temp Sensor Fault — the outdoor air sensor is not reading or is out of range, read as 5 short and… | Failed or drifted outdoor air thermistor | › |
| 55 | Outdoor Coil Sensor Fault — the coil sensor is not reading or is out of range, read as 5 short and 5 long… | Failed or drifted coil thermistor | › |
| 56 | Thermistors Out of Range — an improper relationship between the coil sensor and the outdoor air sensor, read… | One drifted thermistor while the other is accurate | › |
| 71 | Low Stage Thermal Cutout — compressor operation is detected then disappears while low stage demand exists… | Internal compressor overload trip | › |
| 72 | High Stage Thermal Cutout — compressor operation is detected then disappears while high stage demand exists… | Internal compressor overload under high-stage load | › |
| 73 | Contactor Shorted — compressor voltage is sensed when no demand for compressor operation exists, read as 7… | Contactor contacts welded/stuck closed | › |
| 74 | No 230V at Compressor (288A Only) — in the Bryant table this code is scoped to the 288A: compressor voltage… | Contactor stuck open or failed coil (288A) | › |
| 81 | Low Stage Thermal Lockout — a thermal cutout occurs in three consecutive low/high stage cycles, and low stage… | Repeated compressor overload trips (code 71 causes) | › |
| 82 | High Stage Thermal Lockout — a thermal cutout occurs in three consecutive high/low stage cycles, and high… | Repeated high-stage overload trips (code 72 causes) | › |
| 83 | Low-Pressure Lockout — a low pressure switch trip has occurred during 3 consecutive cycles, and unit… | Refrigerant leak with progressively lost charge | › |
| 84 | High-Pressure Lockout — a high pressure switch trip has occurred during 3 consecutive cycles, and unit… | Outdoor fan failure or severely fouled/blocked outdoor coil | › |
All Bryant heat pump models & codes →
Looking for a part?
Once you know the part you need, browse Bryant 286A / 288A replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.