Bryant Heat pump 286A / 288A 46 Error Code

What the 46 code means

Brown Out (230V) — line voltage was less than 187 volts for at least 4 seconds, read as 4 short and 6 long flashes. The Bryant manual states compressor and fan operation are not allowed until voltage is greater than 190 volts, and directs verifying line voltage. The board is protecting the compressor from damaging low voltage; the fault is in the power supply or its connections, not in a refrigerant or sensor part. Occasional events track utility dips; frequent events need the supply investigated.

Likely causes

  1. Utility voltage dip or sustained low voltage
  2. Loose or corroded breaker/disconnect connections dropping voltage under load
  3. Damaged supply wiring
  4. Failing breaker or disconnect

How to fix it — step by step

  1. Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
  2. Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
  3. Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
  4. Measure voltage at the outdoor disconnect: below 187V for 4 seconds trips the code and operation is blocked until above 190V per the manual; re-measure during a start attempt to expose connection voltage drop.
  5. Pinpoint: low or dropping voltage at the disconnect pinpoints the supply, breaker, disconnect or wiring — electrician/utility scope; steady correct voltage with repeated 46 points a technician to the board's sensing.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 46 code

This fault usually does not need a replacement part - the fix is in the steps above. If your heat pump does need a part, start with the link above.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.