Bryant Heat pump 286A / 288A 47 Error Code

What the 47 code means

No 230V at Unit — there is no 230 volts at the contactor when the indoor unit is powered and cooling or heating demand exists, read as 4 short and 7 long flashes. The Bryant manual directs verifying the disconnect is closed and 230V wiring is connected to the unit. The control is calling, but line power never reaches the outdoor unit, so neither compressor nor outdoor fan can operate. This is a power-delivery fault upstream of the refrigerant system.

Likely causes

  1. Outdoor disconnect open or failed
  2. Tripped or failed outdoor-unit breaker
  3. Loose, burnt or disconnected 230V feed wiring
  4. Failed feed connection at the contactor

How to fix it — step by step

  1. Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
  2. Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
  3. Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
  4. Confirm the disconnect is fully closed and the breaker is on; then a technician/electrician measures 230V at the disconnect, the unit line terminals and the contactor to find where power stops.
  5. Pinpoint: restore 230V at the pinpointed disconnect, breaker or wiring fault; power present at the contactor with a persistent 47 pinpoints the board sensing/Contactor circuit for a technician.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 47 code

Parts run $10–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bryant Heat pump 286A / 288A error codes