Bryant Heat pump Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 20 codes covered.

Finding your model number: it is on the outdoor unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

286A / 288A (two-stage)

Codes flash on the control board's amber LED: short flashes (0.25 sec) are the first digit and long flashes (1 sec) the second - 3 short + 2 long is code 32.

CodeWhat it meansCheck first
16System Communications Failure — communication with the User Interface (Evolution Control) is lost, and the…Loose or damaged communication wiring to the Evolution Control, indoor or outdoor unit›
25Invalid Model Plug — the Bryant control does not detect a model plug or detects an invalid model plug, and…Model plug missing after a board replacement›
31High Pressure Switch Open — a high-pressure switch trip, read as 3 short and 1 long flash on the amber status…Outdoor coil blocked or fouled restricting airflow›
32Low Pressure Switch Open — a low-pressure switch trip, and the Bryant manual's own example for reading the…Low refrigerant charge from a leak›
45Control Fault — the Bryant manual states the outdoor unit control board has failed and the control board…Failed outdoor control board circuitry›
46Brown Out (230V) — line voltage was less than 187 volts for at least 4 seconds, read as 4 short and 6 long…Utility voltage dip or sustained low voltage›
47No 230V at Unit — there is no 230 volts at the contactor when the indoor unit is powered and cooling or…Outdoor disconnect open or failed›
53Outdoor Air Temp Sensor Fault — the outdoor air sensor is not reading or is out of range, read as 5 short and…Failed or drifted outdoor air thermistor›
55Outdoor Coil Sensor Fault — the coil sensor is not reading or is out of range, read as 5 short and 5 long…Failed or drifted coil thermistor›
56Thermistors Out of Range — an improper relationship between the coil sensor and the outdoor air sensor, read…One drifted thermistor while the other is accurate›
71Low Stage Thermal Cutout — compressor operation is detected then disappears while low stage demand exists…Internal compressor overload trip›
72High Stage Thermal Cutout — compressor operation is detected then disappears while high stage demand exists…Internal compressor overload under high-stage load›
73Contactor Shorted — compressor voltage is sensed when no demand for compressor operation exists, read as 7…Contactor contacts welded/stuck closed›
74No 230V at Compressor (288A Only) — in the Bryant table this code is scoped to the 288A: compressor voltage…Contactor stuck open or failed coil (288A)›
81Low Stage Thermal Lockout — a thermal cutout occurs in three consecutive low/high stage cycles, and low stage…Repeated compressor overload trips (code 71 causes)›
82High Stage Thermal Lockout — a thermal cutout occurs in three consecutive high/low stage cycles, and high…Repeated high-stage overload trips (code 72 causes)›
83Low-Pressure Lockout — a low pressure switch trip has occurred during 3 consecutive cycles, and unit…Refrigerant leak with progressively lost charge›
84High-Pressure Lockout — a high pressure switch trip has occurred during 3 consecutive cycles, and unit…Outdoor fan failure or severely fouled/blocked outdoor coil›

288BNV Evolution V (variable speed)

Communicating Evolution system faults from the unit's fault label and service table; many carry a timed automatic reset.

CodeWhat it meansCheck first
48Lost Inverter Communications — in the Bryant 288BNV Evolution V service manual's fault label (Fig. 38) and…Loose or disconnected inverter communication harness›
69Inverter / Compressor Internal Fault — in the Bryant 288BNV fault label (Fig. 38), code 69 carries a…Internal inverter drive failure›

Common questions

What does code 48 mean on a Bryant Evolution heat pump?
Lost inverter communications: on the 288BNV Evolution V, code 48 is a system malfunction with a 6-minute reset - communication between the outdoor control and the inverter drive has been lost.

How do I read a Bryant 286A or 288A fault code?
Watch the amber LED on the outdoor control board. Short flashes (a quarter second) give the first digit and long flashes (one second) the second, and the sequence pauses and repeats.

Looking for a part?

Once you know the part you need, browse Bryant Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.