Bryant Heat pump 286A / 288A 56 Error Code
What the 56 code means
Thermistors Out of Range — an improper relationship between the coil sensor and the outdoor air sensor, read as 5 short and 6 long flashes. The Bryant manual directs ohming out the sensors and checking wiring. The control compares the two thermistors continuously; an impossible relationship for the operating mode raises 56 instead of naming one sensor. With an out-of-range error, defrost in heating runs at each interval but terminates early under default operation, cutting heating performance in cold weather.
Likely causes
- One drifted thermistor while the other is accurate
- Coil sensor attached to the wrong tube or loose
- Outdoor air sensor in contact with sheet metal or mislocated
- Crossed or damaged sensor harness wiring
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Ohm out BOTH sensors with power OFF and compare each against the manual's curve at its actual temperature — the one disagreeing with reality is the culprit — and confirm each sensor's mounting location is correct.
- Pinpoint: replace the out-of-specification Thermistor or correct its mounting; both sensors and wiring correct pinpoints the Control board comparison circuit for a technician. → Shop the thermistor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Defrost sensor - Shop at Amazon
Parts that commonly fix the 56 code
- Thermistor$25–$80Shop at Amazon
- Defrost sensor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.