Bryant Heat pump 286A / 288A 74 Error Code

What the 74 code means

No 230V at Compressor (288A Only) — in the Bryant table this code is scoped to the 288A: compressor voltage is not sensed when the compressor should be starting, read as 7 short and 4 long flashes. The manual states the contactor may be stuck open or there is a wiring error. Line power reaches the unit (that is code 47's territory) but does not pass to the compressor on a start call, so the compressor never starts.

Likely causes

  1. Contactor stuck open or failed coil (288A)
  2. Burnt or loose contactor-to-compressor wiring
  3. Open compressor overload or damaged terminals
  4. Control board not energizing the contactor

How to fix it — step by step

  1. Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
  2. Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
  3. Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
  4. Technician, on a start call: 24V at the contactor coil with no 230V on the load side pinpoints the Contactor; no coil voltage points to the Control board/wiring; then verify continuity to the compressor terminals with power OFF.
  5. Pinpoint: replace the Contactor if it will not close on correct coil voltage; otherwise repair the pinpointed wiring or board output — technician job. → Shop the contactor at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 74 code

Parts run $10–$35
  • Contactor$10–$35Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Bryant Heat pump 286A / 288A error codes

See all Bryant 286A / 288A codes & guides →