What the 74 code means
No 230V at Compressor (288A Only) — in the Bryant table this code is scoped to the 288A: compressor voltage is not sensed when the compressor should be starting, read as 7 short and 4 long flashes. The manual states the contactor may be stuck open or there is a wiring error. Line power reaches the unit (that is code 47's territory) but does not pass to the compressor on a start call, so the compressor never starts.
Likely causes
- Contactor stuck open or failed coil (288A)
- Burnt or loose contactor-to-compressor wiring
- Open compressor overload or damaged terminals
- Control board not energizing the contactor
How to fix it — step by step
- Record the amber LED pattern before cycling power: count short flashes (0.25 sec, first digit) then long flashes (1.0 sec, second digit), note any Infinity/Evolution wall-control display of the same code, and photograph the rating plate — power cycles and recycling 24V can clear stored codes or defeat the 15-minute retry delay.
- Safety: switch the outdoor disconnect OFF and the breaker OFF, verify the unit is dead with a meter before touching wiring, and treat the run capacitor as charged until discharged by a technician — do not open the refrigerant circuit.
- Locate the outdoor control board behind the service panel, and the part named in this entry; check access, harness seating, and visible damage, ice, debris, or a clogged indoor air filter first.
- Technician, on a start call: 24V at the contactor coil with no 230V on the load side pinpoints the Contactor; no coil voltage points to the Control board/wiring; then verify continuity to the compressor terminals with power OFF.
- Pinpoint: replace the Contactor if it will not close on correct coil voltage; otherwise repair the pinpointed wiring or board output — technician job. → Shop the contactor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Contactor.
Parts that commonly fix the 74 code
- Contactor$10–$35Shop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bryant manual is on Bryant's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.