York Furnace UPG LED control — single/two-stage (PT9-era, red/green/amber LED) 3 red flashes
What this problem usually means
The pressure switch contact did not close after the inducer was energized on York furnaces with the red/green/amber LED control, so ignition does not start.
Likely causes
- faulty inducer motor → Shop the inducer motor at RepairClinic
- blocked vent pipe
- broken pressure switch hose → Shop the pressure switch at RepairClinic
- faulty pressure switch
- blocked condensate drain on condensing models
How to fix it — step by step
- Check the thermostat is set to Heat and calling for heat
- Check the outdoor vent and intake pipes are clear of snow, ice or debris
- On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
- Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
- If the code returns, stop resetting and call a licensed HVAC technician
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the pressure switch.
Shop the pressure switch at RepairClinic or Amazon
Also tied to this fault: inducer motor - Shop at RepairClinic or Amazon
Parts that commonly fix it
- pressure switch - Shop at RepairClinic or Amazon
- inducer motor - Shop at RepairClinic or Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.
Related York Furnace UPG LED control — single/two-stage (PT9-era, red/green/amber LED) problems
- 4 amber flashes
- 4 red flashes
- 5 red flashes
- 6 red flashes
- 7 red flashes
- 8 red flashes
- 9 red flashes
- Rapid amber flash
- Rapid red flash
- Slow amber flash
- Slow green flash
- Steady on red
See all York UPG LED control — single/two-stage (PT9-era, red/green/amber LED) codes & guides →