York Furnace UPG LED control — single/two-stage (PT9-era, red/green/amber LED) 5 red flashes

What this problem usually means

The rollout switch (normally closed contacts) has opened on York furnaces with the red/green/amber LED control. The rollout control is manual-reset; check combustion air, inducer operation and the heat exchanger before any reset.

Likely causes

  1. flame rollout from the burners
  2. improper combustion air
  3. inducer failure
  4. primary heat exchanger failure or burner problem

How to fix it — step by step

  1. Turn the furnace off at the power switch
  2. Do not reset the rollout switch yourself → Shop the rollout switch at RepairClinic
  3. If anyone has headache or nausea or a CO alarm sounds, leave the building and call from outside
  4. Call a licensed HVAC technician to inspect the burners and heat exchanger → Shop the heat exchanger at RepairClinic

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related York Furnace UPG LED control — single/two-stage (PT9-era, red/green/amber LED) problems