York Furnace Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 19 problems covered.
Shop York Furnace parts at RepairClinic
- 1 red flash — Flame was sensed when there was no call for heat on York furnaces with the red/green/amber LED control. The control runs the inducer and…
- 10 red flashes — Gas valve energized with no call for heat on York furnaces with the red/green/amber LED control. Check the gas valve and gas valve wiring.
- 11 red flashes — A primary or auxiliary limit switch opened and remained open for more than five minutes on York furnaces with the red/green/amber LED…
- 12 red flashes — Open igniter circuit on York furnaces with the red/green/amber LED control. This could be caused by a disconnected or loose wire or by a…
- 2 red flashes — The normally open pressure switch contacts are stuck in the closed position on York furnaces with the red/green/amber LED control. The…
- 3 red flashes — The pressure switch contact did not close after the inducer was energized on York furnaces with the red/green/amber LED control, so…
- 4 amber flashes — The control board is receiving a Y (cooling) signal from the thermostat without a G (fan) signal on York furnaces with the red/green/amber…
- 4 red flashes — A primary or auxiliary limit switch has opened on York furnaces with the red/green/amber LED control. The control runs the blower and…
- 5 amber flashes — Heating capacity is reduced due to a restriction in the combustion air or vent system on York TPLCC modulating furnaces. The manual advises…
- 5 red flashes — The rollout switch (normally closed contacts) has opened on York furnaces with the red/green/amber LED control. The rollout control is…
- 6 red flashes — After the unit was operating, the pressure switch opened 4 times during the call for heat on York furnaces with the red/green/amber LED…
- 7 red flashes — Flame could not be established on York furnaces with the red/green/amber LED control. The no-light condition occurred 3 times during the…
- 8 red flashes — Flame was lost 5 times (4 recycles) during the heating cycle on York furnaces with the red/green/amber LED control. The furnace locks out…
- 9 red flashes — Reversed line voltage polarity or a grounding problem on York furnaces with the red/green/amber LED control. Both heating and cooling…
- Rapid amber flash — Flame sense current is below 1.5 microamps on York furnaces with the red/green/amber LED control. The manual advises checking and cleaning…
- Rapid red flash — Twinning error — incorrect 24V phasing — on York furnaces with the red/green/amber LED control. Check the twinning wiring between paired…
- Slow amber flash — Normal operation with a call for heat on York furnaces with the red/green/amber LED control (including PT9 series). The furnace is running…
- Slow green flash — Normal operation with no call for heat on York furnaces with the red/green/amber LED control (including PT9 series). This is a standby…
- Steady on red — Control failure on York furnaces with the red/green/amber LED control. If the failure is internal to the control, the light stays on…