York Furnace UPG LED control — single/two-stage (PT9-era, red/green/amber LED) 2 red flashes

What this problem usually means

The normally open pressure switch contacts are stuck in the closed position on York furnaces with the red/green/amber LED control. The control checks the contacts are open at the start of each heat cycle.

Likely causes

  1. faulty pressure switch → Shop the pressure switch at RepairClinic
  2. miswiring of the pressure switch
  3. water in the pressure switch hose

How to fix it — step by step

  1. Check the thermostat is set to Heat and calling for heat
  2. Check the outdoor vent and intake pipes are clear of snow, ice or debris
  3. On a high-efficiency model, check the condensate drain line and trap are not clogged or frozen
  4. Turn power off at the furnace switch for 30 seconds, then back on, and try one heat call
  5. If the code returns, stop resetting and call a licensed HVAC technician

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.