York Furnace UPG LED control — single/two-stage (PT9-era, red/green/amber LED) 11 red flashes

What this problem usually means

A primary or auxiliary limit switch opened and remained open for more than five minutes on York furnaces with the red/green/amber LED control. The manual says this is usually caused by a failed blower motor or blower wheel.

Likely causes

  1. failed blower motor → Shop the blower motor at RepairClinic
  2. failed blower wheel
  3. severe airflow restriction

How to fix it — step by step

  1. Turn the thermostat down and let the furnace cool
  2. Replace the air filter if it is dirty or clogged
  3. Open all supply registers and make sure return vents are not blocked by furniture
  4. Restore the heat call and watch whether the code returns
  5. If the limit code repeats, stop and call a licensed HVAC technician

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number inside the blower/burner compartment door. It's the key to the right manual pages and the right parts.

Related York Furnace UPG LED control — single/two-stage (PT9-era, red/green/amber LED) problems