Trane Heat pump Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 15 codes covered.

Not sure of the code? Tap along with it

If your Trane Heat pump blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Finding your model number: it is on the outdoor unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

Demand defrost board (flash counts)

Count the flashes of the Fault LED on the demand defrost control board inside the outdoor control box; the pattern pauses and repeats.

ProblemWhat it meansCheck first
1 flashRead on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault…Open or shorted ambient temperature sensor›
2 flashesRead on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault…Open or shorted coil temperature sensor›
3 flashesRead on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault…Low refrigerant charge from a leak›
4 flashesRead on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault…Repeated low-pressure cut-out trips from low refrigerant charge›
5 flashesRead on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault…Low-pressure cut-out trip from low refrigerant charge›
6 flashesRead on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault…Outdoor (condenser) fan motor failure›
9 flashesRead on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault…Genuinely extreme outdoor temperature below the lockout threshold›

Communicating-system faults show as ERR codes on the ACONT900 comfort control indoors.

CodeWhat it meansCheck first
ERR 126Shown as Err 126 on the Trane ComfortLink comfort control, with no fault reported by the outdoor unit. The…Outdoor unit breaker tripped›
ERR 53Shown as Err 53 on the Trane ComfortLink comfort control. The ACONT900 service manual's Alert Code Response…Loss of power to the outdoor unit, including a tripped outdoor breaker›
ERR 67Shown as Err 67 on the Trane ComfortLink comfort control, with the outdoor Fault LED flashing five times for…Ambient or coil temperature sensor open or shorted›
ERR 79Shown as Err 79 on the Trane ComfortLink comfort control, with the outdoor Fault LED flashing seven times.…System low on refrigerant charge›
ERR 80Shown as Err 80 on the Trane ComfortLink comfort control, with the outdoor Fault LED flashing seventeen…Faulty outdoor fan in cooling›
ERR 89Shown as Err 89 on the Trane ComfortLink comfort control. The ACONT900 service manual's Alert Code Response…Outdoor unit breaker tripped›
ERR 90Shown as Err 90 on the Trane ComfortLink comfort control, with SYS COMM ERR or SYS COMM CRC at the user…R and B wiring reversed at the comfort control or indoor unit›
ERR 91Shown as Err 91 on the Trane ComfortLink comfort control. The ACONT900 service manual gives several Error 91…Data (D) line to the comfort control broken, disconnected, grounded, or reversed with B›

Common questions

What does ERR 90 mean on a Trane ComfortLink system?
A system communication error: the ACONT900 comfort control shows SYS COMM ERR and the alert table lists Err 90 for communication failures between the communicating components.

What do 3 flashes mean on a Trane heat pump?
On the demand defrost board's Fault LED, 3 flashes mean the low pressure switch is open - the low-pressure cut-out has tripped, per Table 3 of the Trane Service Facts for the unit.

Looking for a part?

Once you know the part you need, browse Trane Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.