Trane Heat pump ComfortLink communicating system with ACONT900AC43UA comfort control ERR 90 Error Code
What it should look like on your machine
then it repeats
1 flash - then the pattern repeats. Count along with your machine and compare.
What the ERR 90 code means
Shown as Err 90 on the Trane ComfortLink comfort control, with SYS COMM ERR or SYS COMM CRC at the user interface and, in one variant, one flash on the outdoor unit Fault LED. The ACONT900 service manual's Alert Code Response, Error 90: Communication busy fault, describes excessive communication errors - the comfort control continually attempts to communicate with no idle detected, so the bus is busy. It matters because a jammed communication bus disables coordinated control of the indoor unit, outdoor unit and comfort control even though each component may be individually healthy.
Likely causes
- R and B wiring reversed at the comfort control or indoor unit
- Faulty field control wiring to the comfort control
- A Telephone Access Module out of sequence jamming the bus
- Failed communicating component holding the bus busy
How to fix it — step by step
- Record the code before cycling power: record Err 90 and whether the interface shows SYS COMM ERR or SYS COMM CRC. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
- Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
- Locate the part: inspect the low-voltage field wiring at the comfort control, indoor unit and outdoor unit for reversed R and B connections or damaged cable
- Test: per the manual, disconnect the Telephone Access Module if fitted and recycle power - if the error clears, the module is the cause; otherwise work through the wiring checks before condemning a board
- End point: correct reversed or damaged wiring and replace a module that provably jams the bus. If wiring and module are cleared and the bus stays busy, a technician should isolate components one at a time to find the faulty board. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Control board.
Parts that commonly fix the ERR 90 code
- Control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Trane Heat pump ComfortLink communicating system with ACONT900AC43UA comfort control error codes
See all Trane ComfortLink communicating system with ACONT900AC43UA comfort control codes & guides →