Trane Heat pump 4TWR5042H1000A split system heat pump 5 flashes
What it should look like on your machine
then it repeats
5 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Read on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault Codes, in the Trane Service Facts calls five flashes a soft lock out. The five-flash indication goes away after the soft lockout period expires, and the manual's LPCO tables show escalating timed lockouts - 15 minutes, then 30, then longer - after successive low-pressure trips in heating or cooling. It matters because the unit is deliberately pausing to protect the compressor; a soft lockout that keeps returning is counting toward a hard lockout.
Likely causes
- Low-pressure cut-out trip from low refrigerant charge
- Iced or dirty outdoor coil in heating, or dirty indoor filter in cooling
- Outdoor fan motor failure reducing airflow over the coil
- Intermittent low pressure switch or wiring
How to fix it — step by step
- Record the code before cycling power: count five flashes and wait - note how long the unit stays off, since lockout length grows with repeat trips. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
- Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
- Locate the part: the defrost board is in the outdoor control box; inspect the indoor air filter, the outdoor coil for ice or debris, and confirm the outdoor fan runs on a call
- Test: if the unit restarts after the timed period and the fault does not return, monitor it; if five flashes recur, a technician with gauges must check suction pressure and the low pressure switch circuit rather than guessing at charge
- End point: fix simple airflow causes - clean filter, clear coil - yourself; recurring soft lockouts need a pro to correct charge or switch faults before they escalate to the four-flash hard lockout. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air filter.
Also tied to this fault: Outdoor fan motor - Shop at Amazon; Defrost control board - Shop at Amazon
Parts that commonly fix it
- Air filter$5–$30Shop at Amazon
- Outdoor fan motorShop at Amazon
- Defrost control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Trane Heat pump 4TWR5042H1000A split system heat pump problems
See all Trane 4TWR5042H1000A split system heat pump codes & guides →