Trane Heat pump ComfortLink communicating system with ACONT900AC43UA comfort control ERR 80 Error Code
What the ERR 80 code means
Shown as Err 80 on the Trane ComfortLink comfort control, with the outdoor Fault LED flashing seventeen times. The ACONT900 service manual's Alert Code Response, Error 80: High pressure monitor fault, describes liquid pressure rising above 595 PSIG then falling below 535 PSIG five times within the same call, producing a hard lockout that is reset by cycling power. It matters because repeated high-pressure excursions stress the compressor and usually mean heat cannot leave the system - a fan or airflow failure, or an overcharge - rather than a bad switch alone.
Likely causes
- Faulty outdoor fan in cooling
- Faulty indoor blower in heating
- Refrigerant overcharge
- Outdoor airflow restriction in cooling or indoor airflow restriction in heating, including a dirty filter
- Wiring to the high pressure switch open or shorted
How to fix it — step by step
- Record the code before cycling power: record Err 80 and the mode in use before cycling power. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
- Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
- Locate the part: confirm the outdoor fan runs in cooling and the indoor blower runs in heating; inspect coils and replace a dirty indoor air filter
- Test: a technician with gauges confirms liquid pressure actually reaches the manual's 595 PSIG trip region; normal pressures with a tripping indication point to the high pressure switch or its wiring instead
- End point: restore failed fan or blower operation - a tested-bad outdoor fan motor or run capacitor can be replaced - while overcharge correction and any sealed-system work is pro only. Do not keep resetting a hard lockout. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Outdoor fan motor.
Shop the Outdoor fan motor at Amazon
Also tied to this fault: Run capacitor - Shop at Amazon; Air filter - Shop at Amazon
Parts that commonly fix the ERR 80 code
- Outdoor fan motorShop at Amazon
- Run capacitor$5–$35Shop at Amazon
- Air filter$5–$30Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related Trane Heat pump ComfortLink communicating system with ACONT900AC43UA comfort control error codes
See all Trane ComfortLink communicating system with ACONT900AC43UA comfort control codes & guides →