Trane Heat pump ComfortLink communicating system with ACONT900AC43UA comfort control ERR 80 Error Code

What the ERR 80 code means

Shown as Err 80 on the Trane ComfortLink comfort control, with the outdoor Fault LED flashing seventeen times. The ACONT900 service manual's Alert Code Response, Error 80: High pressure monitor fault, describes liquid pressure rising above 595 PSIG then falling below 535 PSIG five times within the same call, producing a hard lockout that is reset by cycling power. It matters because repeated high-pressure excursions stress the compressor and usually mean heat cannot leave the system - a fan or airflow failure, or an overcharge - rather than a bad switch alone.

Likely causes

  1. Faulty outdoor fan in cooling
  2. Faulty indoor blower in heating
  3. Refrigerant overcharge
  4. Outdoor airflow restriction in cooling or indoor airflow restriction in heating, including a dirty filter
  5. Wiring to the high pressure switch open or shorted

How to fix it — step by step

  1. Record the code before cycling power: record Err 80 and the mode in use before cycling power. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
  2. Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
  3. Locate the part: confirm the outdoor fan runs in cooling and the indoor blower runs in heating; inspect coils and replace a dirty indoor air filter
  4. Test: a technician with gauges confirms liquid pressure actually reaches the manual's 595 PSIG trip region; normal pressures with a tripping indication point to the high pressure switch or its wiring instead
  5. End point: restore failed fan or blower operation - a tested-bad outdoor fan motor or run capacitor can be replaced - while overcharge correction and any sealed-system work is pro only. Do not keep resetting a hard lockout. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the ERR 80 code

Parts run $5–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Trane Heat pump ComfortLink communicating system with ACONT900AC43UA comfort control error codes

See all Trane ComfortLink communicating system with ACONT900AC43UA comfort control codes & guides →