Trane Heat pump 4TWR5042H1000A split system heat pump 6 flashes

What it should look like on your machine

then it repeats

6 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Read on the Fault LED of the demand defrost control board inside the outdoor control box. Table 3, LED Fault Codes, in the Trane Service Facts states defrost cycles are too close together. The manual explains a heating short-cycle fault triggers the six-flash code: defrosts arriving within about 15 minutes of accumulated heating time push the control into an adaptive limp mode for ten heating cycles before it returns to demand defrost. It matters because excessively frequent defrost wastes heat, and the manual names a failed condenser fan motor or low charge among the underlying causes.

Likely causes

  1. Outdoor (condenser) fan motor failure
  2. Low refrigerant charge
  3. Coil or ambient sensor reading incorrectly and calling false defrosts
  4. Heavily frosted or blocked outdoor coil

How to fix it — step by step

  1. Record the code before cycling power: count six flashes and time how often defrosts occur during a heating call. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
  2. Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
  3. Locate the part: watch the outdoor fan through a heating cycle - it should run whenever the compressor heats, stopping only during defrost; the defrost board is in the outdoor control box
  4. Test: confirm the fan motor runs and is not stalled or seized, and check the coil is not matted with debris or ice; sensor resistance can be compared with the Service Facts chart, and only a technician with gauges can confirm low charge
  5. End point: replace a failed outdoor fan motor or its run capacitor if tested bad; sensor faults go back to the one- and two-flash checks. Suspected low charge is pro work - do not add refrigerant on this code alone. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Working on a specific model? The official Trane manual is on Trane's support site — you'll need your model number.

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.