Peerless Boiler Pinnacle (PI / PI-T) series, PI25 control FLu Error Code

What the FLu code means

An error display, not a numbered code: the blocked vent pressure switch is open, and it stays displayed until corrected. The boiler is proving its vent path before firing, and an open switch means the vent is blocked or the switch itself has failed. Firing a boiler into a blocked vent is dangerous, so the control will not try.

Likely causes

  1. Blocked vent or flue passage
  2. Failed blocked vent pressure switch
  3. Blocked or disconnected switch sensing line

How to fix it — step by step

  1. Record the display exactly as shown, FLu, before resetting anything.
  2. Safety: do not jumper this switch to run the boiler except as a brief attended test. A genuinely blocked vent can spill flue gas into the building.
  3. Locate the vent and flue path from the boiler to its termination, and the blocked vent pressure switch and its sensing line inside the boiler.
  4. Test: inspect the full vent run and termination for blockage, nests, ice or collapsed sections. A clear vent with the display still shown is proven by temporarily applying a jumper: clearing on the jumper with a verified clear vent condemns the switch.
  5. End at the fix: clear any vent blockage found and retest. If the vent is clear and the jumper test cleared the display, replace the blocked vent pressure switch. → Shop the blocked vent pressure switch at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the FLu code

Parts run $50–$205

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Peerless Boiler Pinnacle (PI / PI-T) series, PI25 control error codes