Peerless Boiler Pinnacle (PI / PI-T) series, PI25 control PRO Error Code

What the PRO code means

An error display, not a numbered code: the water pressure switch is open, and it stays displayed until corrected. The boiler will not run with the switch open because it cannot prove the system has enough water pressure. The switch opens when system pressure falls to the boiler minimum, around 10 psig.

Likely causes

  1. System pressure at or below 10 psig
  2. Leak in the system piping losing pressure
  3. Failed water pressure switch

How to fix it — step by step

  1. Record the display exactly as shown, PRO, and read the system pressure on the combination gauge in the supply piping.
  2. Safety: do not jumper the pressure switch to run the boiler as a permanent fix. A jumper is a test only, with the boiler attended.
  3. Locate the water pressure switch on the boiler and the combination pressure and temperature gauge in the supply piping on the left side of the boiler.
  4. Test: pressure above 10 psig on the gauge with PRO still displayed means the switch or its wiring is at fault, proven by temporarily applying a jumper: if the display clears on the jumper, the switch is not closing. Pressure genuinely below 10 psig means find where the water went.
  5. End at the fix: restore system pressure above 10 psig and repair any piping leak found. If pressure is correct and the jumper test cleared the display, replace the water pressure switch. → Shop the water pressure switch at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the PRO code

Parts run $50–$205

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Peerless Boiler Pinnacle (PI / PI-T) series, PI25 control error codes

See all Peerless Pinnacle (PI / PI-T) series, PI25 control codes & guides →