Peerless Boiler Pinnacle (PI / PI-T) series, PI25 control NC Error Code
What the NC code means
A fault display: neutral fault. The boiler locks out if it senses a voltage drop or power feedback on the neutral wire. This is a building wiring problem reaching the boiler, not a boiler part failure, and the boiler is protecting itself from unreliable power.
Likely causes
- Inadequate supply voltage to the boiler
- Power feedback on the neutral wire from another circuit or a wiring fault
How to fix it — step by step
- Record the display, NC, before resetting.
- Safety: work on supply wiring and neutral faults is electrician work. Switch off the boiler circuit at the breaker before any wiring inspection.
- Locate the boiler power supply connection and the circuit feeding it back to the panel.
- Test: check for adequate supply voltage at the boiler with a meter, and check for voltage appearing on the neutral wire that should not be there. Correct voltage with no neutral feedback and the fault still set means the supply problem is intermittent and needs an electrician's load testing.
- End at the pinpointed cause: correct the supply voltage problem or the neutral feedback at its source in the building wiring. No boiler part is replaced for this fault. Reset and confirm the boiler runs on clean power.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the fault is internal - there is no documented owner fix beyond the steps above. If you're not comfortable taking it apart yourself, a repair shop is the next step.
Parts that commonly fix the NC code
No specific replacement part is documented for this fault. If the checks above do not clear it, your boiler likely needs to be disassembled and an internal part replaced - and since the manufacturer publishes no procedure for that, it is the point where most owners hand it to a repair shop.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Peerless Boiler Pinnacle (PI / PI-T) series, PI25 control error codes
See all Peerless Pinnacle (PI / PI-T) series, PI25 control codes & guides →